Current Location:homepage > News center > Industry news

Hunan elevator maintenance of 22 fault codes

Release time: 2018-09-19 09:03:59

News source: Hunan Alpha Elevator Engineering Co., LTD

                                           Hunan Elevator22 fault codes for repair

This content is provided by,Hunan Elevator Company, Alpha elevator collection,Code applicable to KONE elevators, other elevators cannot apply。

Fault code

Fault description

cause

Elevator condition

Fault repair

0165

The elevator door contact monitoring function is activated。

The elevator hall door contact or car door contact is disconnected。

The elevator stopped running immediately。

 

0169

Elevator emergency battery voltage is over。

LCE CCB board detects emergency battery voltage or damage to car roof

The elevator has no emergency lighting function。

Replace the emergency battery。

0170

The AC power supply voltage fails。

 

 

Check the elevator power supply circuit。

0171

24V control voltage failed。

 

 

Check the elevator power supply circuit。

0172

24V elevator car or shaft supply voltage problem。

 

 

Check the elevator power supply circuit。

0101

Drive stop。

The drive system stops running after detecting a fault。

 

Check other fault codes。

0102

Motor overcurrent。

Elevator drive system detected motor overcurrent。

 

Check elevator motor。

0103

Elevator brake resistance is faulty。

Elevator brake resistance is damaged。

 

Replace the elevator brake resistance。

0104

Elevator motor overheating。

Elevator motor thermistor action。

 

 

0106

Elevator inverter function problem。

Elevator converter overheats。

 

 

0107

The elevator weighing device is faulty。

There is a problem with the output signal of the elevator weighing device。

 

Re-adjust or replace the elevator weighing device。


Fault code

Fault description

cause

Elevator condition

Fault repair

0108

The elevator motor or speed motor is faulty。

Wrong polarity of elevator speed motor or elevator balance problem。

Elevator not working。

 

0109

The elevator drive system is missing。

 

The elevator automatically returns to the terminal to find its position。

The elevator will resume automatically when it returns to the terminal。

0110

Elevator brake resistance thermal protection action。

Elevator brake resistance overheats。

Lift out of service

 

0111

Flat layer sensor plate 61:N under 61:U。

 

 

Change the position of the flat layer sensor plate 61:N at 61:U。

0112

Flat layer sensor 61:N overlaps too little at 61:U。

 

 

Adjust the overlap distance of the flat layer sensor plate 61:N in 61:U according to the drawing。

0113

Elevator synchronization 77: S failure。

 

 

Check or replace the 77: S of the elevator。

0114

The elevator floors are too far apart。

The distance between the adjacent two floors of the elevator is the specified floor distance。

 

Check the distance of the elevator floor sensor。

0115

Elevator scale problem。

The TACHO voltage setting of the elevator caused the speed of the elevator to be incorrect when the shaft was set。

 

 

0116

Wrong elevator floor count。

The number of floors shown by the elevator does not match the reality。

 

Redo the elevator shaft Settings。

0125

Elevator rotation exceeds the limit。

 

The elevator stopped running immediately and could not be started。

 

0126

Elevator safety circuit contactor open。

 

Elevator not working。

 

提醒:Elevator maintenanceThere are risks, non-professionals do not disassemble, so as to avoid accidents。

If you are in Hunan and need elevator maintenance service, please dialHunan ElevatorMaintenance hotline: 13874931818

Hot spot recommendation