Hunan Elevator Company, Alpha Hunan elevator maintenance for you6个Kone Elevator Repair fault code,For the reference of elevator maintenance personnel, non-professionals do not operate alone, each brand of elevator maintenance fault code is different, can not be applied。
Attention should be paid to maintenanceKone elevator maintenance fault code principle: the new fault code will crowd out the previous fault code, after the maintenance personnel eliminate a problem, should check whether the fault code control panel also prompts other fault codes, elevator maintenance has a certain dangerous system, professional difficulty is higher, please be careful to operate the maintenance personnel。
Hunan elevator maintenance fault code: applicable to KONE elevator
故障代码 |
Fault description |
cause |
Elevator condition |
Fault repair |
0001 |
The drive out-of-time monitoring protection function is enabled。 |
When the elevator motor rotates beyond the time set by the software, the elevator car position detection signal does not send any change signal。 |
The elevator stopped running immediately。 |
Check the car top position detection sensor。 Cut off the elevator power reset。 |
0004 |
Three consecutive synchronization failures。 |
During three consecutive synchronous operation of the system, signals such as 77: U/N, 61: U/N and 30 were wrong, and the elevator location was not found。 |
The elevator stops at the terminal。 |
Check the car top position detection sensor。 Cut off the elevator power reset。 |
0007 |
Gate 30 or B30 signal is active for a long time。 |
After the elevator starts, the door area 30 sensor moves, and the system does not detect the elevator leaving the door area。 |
The elevator opens and stops on the floor。 |
Check the door area sensor。 Cut off the elevator power reset。 |
0008 |
The NV RAM on the LCE CPU board is faulty. Procedure。 |
NV RAM Memory too。 |
|
Replace the NV RAM。 |
0014 |
Gate monitoring loop not released。 |
The ADO /ACL (with early opening function) loop, i.e., the contactor 486/443:1/443:2, is not released during two consecutive runs of the elevator。 |
The elevator stops at the hall door。 |
Power off reset after check recovery。 |
0015 |
Gate monitoring loop not released。 |
The ADO /ACL (with early opening function) loop, i.e., the contactor 486/443:1/443:2, is not released during two consecutive runs of the elevator。 |
The elevator stops at the hall door。 |
Power off reset after check recovery。 |
Hunan Elevator CompanyAlphaHunan elevator maintenanceProvide elevator related information or news every day, if you need to see more elevator news consultation or knowledge, please check in the news center。Hunan Elevator CompanyAlpha Hunan elevator maintenance to undertake: Hunan elevator maintenance, Changsha elevator maintenance, Hunan elevator installation, Changsha elevator installation and other businesses, skilled, quick response, customer reputation。
Previous page:Hunan elevator maintenance 16 fault codes
Key words: Changsha elevator maintenance Hunan elevator maintenance Hunan Elevator Company Hunan Elevator
Related articles:
Elevator engineering construction requirements 1, electric drive traction or forced elevator construction requirements 1.Elevator equipment approach acceptance (1) Equipment approach inspection...
Safety management is the management of people, things and environmental factors in production, effectively controlling the insecure behavior of people and the insecure state of things, and avoiding accidents...
Question 1 about some elevators.Purpose and significance of elevator maintenance Elevator maintenance refers to the regular inspection, refueling and removal of dust accumulation of the operating elevator components...
Elevator as an important building special equipment, the total assembly is completed in the construction site, elevator installation quality is crucial to improve the overall quality of the project...