Kone elevator repair 16 common fault codes
Fault code |
Fault description |
cause |
Elevator condition |
Fault repair |
0021 |
Safety loop disconnection。 |
The safety contact of one or more safety components in the safety loop is disconnected。 |
The elevator stopped running immediately。 |
Check the cause of the operation of the safety loop, troubleshoot the fault, and restore the safety loop。 |
0022 |
During the operation of the elevator, the hall door contact is disconnected for some reason。 |
The elevator hall door is not adjusted well, resulting in poor safety contact or artificial opening of the hall door。 |
The elevator stopped immediately。 |
Check the elevator hall door。 |
0023 |
When the elevator is running, the car door contact is disconnected for some reason。 |
The elevator car door is not properly adjusted, resulting in poor safety contact。 |
The elevator stopped immediately。 |
Check the elevator car doors。 |
0025 |
The start enable signal is faulty。 |
Main contactor not released or poor contact。 |
Elevator does not start。 |
Check the elevator main contactor and its radial contact。 |
0026 |
Drive system failure |
The elevator drive module is faulty and the 'V3F OK' light is not on。 |
Elevator does not start。 |
Check the elevator drive module and peripherals connected to it。 |
0036 |
Not In Use |
|
|
|
0039 |
77: U/N temporary jumper button action。 |
The 77: U/N temporary jumper button on the LCE CPU is pressed。 |
Elevator does not start。 |
The elevator will resume automatically when the 77: U/N temporary jumper button is normal。 |
0042 |
Car lighting monitoring function。 |
The CPU detects no voltage in the car lighting loop。 |
Elevators can't run fast。 |
Check car lighting circuit and safety。 |
0044 |
Elevator closing fault |
The elevator automatically closes 5 times, but the CPU does not detect a 'DOOR CONTACT' or 'SHAFT DOOR CONTACT' signal。 |
The elevator automatically opens the doors and stops on the floor。 |
Check car door contact or hall door contact function。 |
Fault code |
Fault description |
cause |
Elevator condition |
Fault repair |
0048 |
The operation time of the elevator reopening device is more than 1 minute。 |
Elevator car door protection device operation time exceeds 1 minute。 |
The elevator is kept open。 |
Check the function of elevator door protection devices, such as light curtains or safety touchpads, or remove obstacles blocking elevator car doors。 |
0049 |
The closing time is too long。 |
Elevator car door closing limit signal is lost。 |
After the elevator tries to close the door for 5 more times, the elevator car door is opened, and at the same time, the fault code 0044 appears。 |
Check the closing limit signal of the door engine system。 Power off reset elevator。 |
0051 |
Elevator startup failure。 |
Incorrect lift weight setting or lift drive parameter setting or drive failure。 |
After trying to start the elevator for 5 times, the elevator still cannot run, and then the door is opened and the elevator is stopped。 |
Check the elevator scale Settings, check the elevator drive or drive parameter Settings。 |
0052 |
The forced deceleration at the top and bottom of the elevator shaft works simultaneously。 |
The forced deceleration 77: U and 77: N at the top and bottom of the elevator shaft operate simultaneously。 |
The elevator stopped running immediately。 |
Check the position and orientation of the magnets for forced deceleration installed at the top and bottom of the elevator shaft。 |
0058 |
No drive time output。 |
The elevator does not start for 100 seconds after receiving the drive command。 |
The elevator is trying to restart。 |
Automatic recovery。 |
0060 |
Elevator 'pick up' signal lost。 |
During the operation of the elevator, the elevator control system did not receive the 'pick up' signal from the elevator drive system。 |
The elevator will automatically run to the terminal。 |
Automatic recovery。 |
0061 |
Forced closing time is too long。 |
The elevator door system is faulty, which prevents the door from being closed。 |
The elevator tried to close the door automatically four times, and after failure, 0044 fault was displayed at the same time。 |
Check the door engine system and remove obstacles blocking the door system。 |
Hunan ElevatorMaintenance company, Alpha elevator friendship reminds you, elevator maintenance, need to be careful, do not be impatient, maintenance work, please arrange the maintenance work plate, so as to avoid tourists do not know, accidents, maintenance, please first power off, pay attention to personal safety。The above fault code may be replaced, please do not operate alone, need to ask a professional company responsible for maintenance。
Hunan Elevator CompanyAlpha Elevator is an experienced elevator maintenance service company, focusing on elevator maintenance,Elevator installationMore than 10 years, only for more professional, good service, quick response。Hunan elevator maintenance, find Hunan Alpha elevator Co., LTD。
Previous page:Hunan elevator maintenance 12 fault codes
Next page:Hunan elevator maintenance 6 fault codes
Key words: Hunan elevator installation Changsha elevator maintenance Hunan elevator maintenance Hunan Elevator Company
Related articles:
Elevator engineering construction requirements 1, electric drive traction or forced elevator construction requirements 1.Elevator equipment approach acceptance (1) Equipment approach inspection...
Safety management is the management of people, things and environmental factors in production, effectively controlling the insecure behavior of people and the insecure state of things, and avoiding accidents...
Question 1 about some elevators.Purpose and significance of elevator maintenance Elevator maintenance refers to the regular inspection, refueling and removal of dust accumulation of the operating elevator components...
Elevator as an important building special equipment, the total assembly is completed in the construction site, elevator installation quality is crucial to improve the overall quality of the project...